The Si-Trap™: True Multi-Omics Sample Prep

The Si-Trap™: fast, reproducible single-sample multi-omics!Multi-omics has enormous scientific value: biomolecules don't act in isolation and proteins, metabolites and lipids work together to effect life. Analyzing them together reveals more than studying any single class yet sample prep workflows remain omics-specific: split a sample (or get sequential slices) and independently work up each fraction. That's more handling, more variability and less confidence that the resulting datasets are truly paired: sample preparation and pre-analytical variation tend to be the largest sources of variability. Sample prep has simply lagged behind our multi-omics advances; we needed a better solution! Some approaches tried to address this. Methyl tert-butyl ether (MTBE)-based biphasic extraction (1) can separate a sample into a lipid-rich organic phase, an aqueous metabolite phase, and an insoluble protein-containing residue. SIMPLEX (2) built on this concept using a water/methanol/MTBE extraction, but at the cost of substantial sample manipulation that clogs automation. The Si-Trap™ was designed to solve that problem: one sample, multiple molecular classes, one integrated workflow (3). It gives truly integrated multi-omics sample preparation from a single sample. No splitting, no separate sample prep pipelines and no pellet handling. One protocol generates multiple analysis-ready omics fractions from the same biological input. It is designed for automation and delivers single-digit coefficients of variation. It's especially helpful where you have limited-input samples, biopsies or translational studies: all the situations where sample splitting increases variability and reduces data quality. The workflow begins with strong, detergent-free sample dissolution. After neutralization and denaturation with organic solvent, proteins are captured within derivatized Si-Trap™ pores through weak-affinity interactions. Metabolites and lipids pass through in a mass spectrometry-compatible format. The trapped proteins are then processed and digested in situ with the protease of choice to yield analysis-ready peptides. For a separate lipid fraction, use the optional lipid solution. In ProtiFi’s HuH-7 cell comparison, Si-Trap™ matched or exceeded standard S-Trap™ proteomic depth while producing higher signal for 93% of detected metabolites compared to a conventional acetonitrile extraction. Multi-omics sample preparation should be simple, reproducible, scalable and practical for real-world labs. Since sample preparation is already part of every workflow, why not recover all the major molecular fractions from the same sample? One sample in, multiple molecular classes and integrated biology out! Read more about Si-Trap™ in our previous post here. ReferencesMatyash V, Liebisch G, Kurzchalia TV, Shevchenko A, Schwudke D. Lipid extraction by methyl-tert-butyl ether for high-throughput lipidomics. J Lipid Res. 2008;49(5):1137–1146.Coman C, Solari FA, Hentschel A, Sickmann A, Zahedi RP, Ahrends R. Simultaneous Metabolite, Protein, Lipid Extraction (SIMPLEX): A Combinatorial Multimolecular Omics Approach for Systems Biology. Mol Cell Proteomics. 2016;15(4):1453–1466.Zougman A, Wilson JP, Roberts LD, Banks RE. Detergent-Free Simultaneous Sample Preparation Method for Proteomics and Metabolomics. J Proteome Res. 2020;19(7):2838–2844.  

By |2026-04-14T19:30:56+00:00Apr 14, 2026|Article|0 Comments

How the Si-Trap™ Enables True Multi-Omics: From Proteins, to Lipids, to Metabolites, All in One Workflow

Multi-omics workflows promise deeper biological insight, but sample preparation remains a significant bottleneck. Proteomics and metabolomics are typically collected in separate, parallel workflows, increasing handling and technical variability. Without a unified approach that generates multiple analysis-ready fractions from a single sample, reproducibility and scalability become harder to achieve.   To address this need, we present the Si-Trap™ (Simultaneous Trapping), a high-throughput, detergent-free multi-omics sample preparation platform designed to separate and capture proteins, lipids, and metabolites from one sample with inter- and intra-run reproducibility. The workflow starts with detergent-free lysis, followed by neutralization and organic-solvent denaturation. Proteins are captured within derivatized pores through weak-affinity interactions, while metabolites flow through as a small-molecules fraction compatible with direct mass spectrometry analysis. Trapped proteins are processed in situ on the 96-well plate (denaturation, reduction, and alkylation), digested with the user’s protease of choice, and peptides are subsequently eluted for LC-MS. We also offer an optional lipid extraction solution, that allows for biphasic separation and collection of lipids from the same sample.   Using HuH-7 cells under PFAS exposure as a representative model, we found that Si-Trap™ matched standard S-Trap™ proteomics depth while outperforming a standard ACN:MeOH extraction for 39 of 42 detected metabolites, delivering 1.0- to 7.5-fold higher signal. The Si-Trap™ also detected trends in biologically relevant metabolites that were not observed with the standard workflow. The Si-Trap™ can outperform conventional metabolomics extraction methods, without compromising proteomic recovery and depth.  By eliminating parallel prep workflows, Si-Trap™ reduces handling and variability while supporting scalable, automation-ready processing in a 96-well format. The result is a practical, time-saving, and cost-effective path to reproducible multi-omics sample preparation. Spend less time splitting samples and troubleshooting prep, and more time generating LC-MS data you can trust. Ongoing work is evaluating additional molecular classes to further expand coverage and maximize information recovered from samples.  Be on the lookout- Si-Trap™ is launching this month! 

By |2026-03-10T17:29:16+00:00Mar 10, 2026|Article|0 Comments

What to Expect at US HUPO 2026: New Technologies and Where to Find ProtiFi

Catch ProtiFi at US HUPO 2026 in St. Louis, MO at booth #21! We are excited to join leading scientists, researchers, and industry experts on the cutting edge of science on February 22 – 25th. What should you expect to see from ProtiFi? Check it out below. The highly sought after, first of its kind, multi-omics technology, the Si-Trap™. Be the first to see this industry leading technology set to launch in March. The Si-Trap™ is perfect for those with precious samples and looking for a cost-effective solution; allowing preparation of lipids, metabolites, and proteins all in one workflow! Find more information here or visit our poster during Poster Session 1 at poster P16.25. Do you have a need for more rapid sample preparation? Come by and check out the S-Trap™ Turbo™ Mini Plate and Kit. Stronger binding with less capture matrix allows smaller elution volumes elimination the need for additional concentration steps (and time). Designed for high-throughput workflows, the S-Trap™ Turbo™ integrates seamlessly into 96-well processing and automation platforms, making it well-suited for large cohort studies, discovery proteomics, and comparative screening applications. Need help with data analysis? SimpliFi™ makes organizing and visualizing complex omics data simple. Stop by our poster during Poster Session 2 at poster P04.14. Stop by the ProtiFi booth and we would be happy to discuss any of these new exciting products with you as well as the newly released S-Trap™ Micro Plate and other S-Trap™ products!

By |2026-02-27T02:08:21+00:00Feb 20, 2026|Article|0 Comments
Go to Top